Item category Oscilloscopes & Scopemeters
|
![]() General Introducing the Industrial ScopeMeter Test Tool: More Ways to Find The Trouble Fast The new Fluke 123 Industrial ScopeMeter test tool is the ideal choice for troubleshooting industrial machinery, instrumentation, control, and power systems. Its innovative, easy-to-use features save time and help minimize downtime in production and manufacturing systems. Scope, Meter and Recorder in one handheld package. Combines the three most frequently used service tools in one. Connect-and-View™ hands-off operation for checking an entire troubleshooting sequence without ever touching a button. Checks and troubleshoots AC and DC motor drives, sensors and actuators, line voltage, transformers and converters, analog and digital control loops. Single, shielded test lead measures all functions for intuitive ease of use. Fits easily in your hand - just 2.5 lb./1.2 kg. Safety-designed and certified for measurements on 600Vdc, 600 Vac rms/(1700Vpk-pk) CAT III industrial power systems. Affordable. Features Make A Full Sequence of Measurements Without Ever Having To Adjust The Tool Scope users know how frustrating triggering can be. The wrong trigger settings show unexpected, unrecognized, and sometimes wrong results. The Fluke 123 Industrial ScopeMeter recognizes signal patterns and automatically sets up correct triggering, to always provide a stable display of even the most complicated signals - including motor drives and control signals. Fast Fault Finding with Connect-and-View™ "Connect-and-View" hands-off operation provides rock stable, reliable and repeatable displays of signals without touching a button. All signal detail is revealed including spikes and noise. Even complex signals are triggered automatically and flawlessly. The Fluke 123 features unique "single test lead does all measurements" providing intuitive ease of use. You can use one and the same set of test leads for waveform display, multiple meter readings, capacitance and resistance measurements, and continuity checking. There's no need to swap leads. Troubleshooting scenario: An automatic wave soldering machine shows occasional "hiccups". Printed circuit boards don't move along. What's wrong? Follow this quick sequence of tests to find the problem. 1. Check the line power. The Fluke 123 adjusts automatically. Display AC volts. Look at the waveform. It shows distortion (harmonics) and noise. Move the test leads to the power supply. There's no need to readjust the Fluke 123. 2. Check the DC power to the control unit. The DC voltage level is correct. The ripple appears okay and no spikes are visible, so the power supply and filters check out. 3. Move on to the control signal from the digital board. There's no need to touch a button. The Fluke 123 sets tself up automatically. You can perform all of these checks while holding the test leads. No adjustments to the ScopeMeter are necessary. The display is always correct and stable. Connect-and-View™ allows for quick and reliable checks of many test points in a quick sequence with a minimum of errors. Battery power provides isolation from ground and delivers optimum mobility with no line cords or ground wire to get in the way of getting good measurements. The Fluke 123 Industrial ScopeMeter streamlines troubleshooting tasks making you and your team more efficient. Specifications Dual Input Oscilloscope Vertical Bandwidth: 20 MHz at inputs With STL120 1:1 leads: 12.5 MHz With PM 8918 10:1 probes(optional): 20 MHz Coupling: AC, DC Sensitivity: 5 mV/div to 500 V/div Vertical resolution: 8 bit Accuracy: ± (2% of reading +0.05 x range/div) Horizontal Range: 20 ns/div to 60 s/div Acquisition modes: Normal, Single, Roll, Envelope, Smooth Max. sample rate: 1.25 GS/s for repetitive signals 25 MS/s for single shot Record length: 512 samples per channel Accuracy: ± (0.1% of reading +0.04 x time/div) Glitch capture: 40 ns or longer Trigger Source: A or B. External via optional ITP120 Modes: Auto, Triggered, Single NTSC, PAL, PAL+, SECAM Pre-trigger: Up to 10 divisions of pre-trigger view Measurements VDC, VAC, VAC+DC, Vpeak, Vpeak-peak, Frequency, Duty Cycle, Pulse Width and Phase. Measurements can be scaled to Amps Memory 2 screens, 10 user setups Dual Input 5000 count Autoranging Meter DC Voltage VDC Ranges: 500 mV, 5V, 50V, 500V, 1250V Accuracy: ± (0.5% + 5 counts) True RMS Voltage VAC and VAC+DC Ranges: 500 mV, 5V, 50V, 500V, 1250V Accuracy: ± (1% + 10 counts) Additional Measurements and Functions Ohms, Continuity, Diode Test, Amps, ºC or ºF, Capacitance, dBV, dBm, Crest Factor, Touch Hold and ZeroSet. (Amps, ºC or ºF with optional probes) Graphs meter readings of the MIN and MAX values from 120 seconds to 16 days. TrendPlot Automatic vertical scaling and time compression. Displays the actual and MIN, MAX or AVG reading. Optically Isolated RS-232 Interface To printer supports HP LaserJet®, DeskJet®, Epson FX/LQ and Postscript To PC dump and load settings and data, compatible with FlukeView® Software SW90W/012E for Windows Warranty 3 years parts and labor General Specifications Display Cold cathode fluorescent backlit LCD. Contrast and brightness user adjustable. Wide viewing angle. Size: 72x72 mm (2.8x2.8 inch) Power Line voltage adapter/battery charger included: Installed battery: Rechargeable NiCd pack Operating time: Up to 5 hours Charging time: 4 hours Environmental Temperature: 0ºC to 50ºC Environmental MIL-T-28800E, Type III, Class 3, Style B: Electro-Magnetic Compatibility Emission: EN50081-1(1992): EN55022 and EN60555-2 Immunity: EN50082-2(1992): IEC1000-4-2, -3, -5 Enclosure protection: IP51, IEC529 (dust, drip proof) Mechanical Data Size: 50x115x232 mm (2x4.5x9.1 inches) Weight: 1.2 kg (2.5 lb.) Safety Designed for measurements on 600V Overvoltage Category III Installations, Pollution Degree 2, per: ANSI/ISA S82.01-1994 EN61010.1 (1993) (IEC1010-1) CAN/CSA-C22.2 No. 1010.1-92 UL3111-1 Surge protection: 6 kV on input A and B Floating measurements: 600 Vrms from any terminal to ground Accessories Please Call Model FLK-123/003 Fluke 123 Industrial ScopeMeter FLK-123/003S * Fluke 123 Industrial ScopeMeter Opt. SCC *Fluke 123 Opt. SCC includes: Hard-shell Carrying Case, Optically Isolated RS-232 Adapter/Cable, two BB120 Shielded Banana to BNC Adapters and FlukeView for ScopeMeter Windows® software. Please select from the drop down menu below © 2006 Omni Controls, Inc.. All Rights Reserved. Email: Sales@Omnicontrols.com We guarantee a 24 hour response on all inquiries made via email. For quicker response please call Omni Controls at any of the above numbers |