  Fluke 787 ProcessMeter Loop Calibrator

Features

Fluke combined the DMM you trust with the loop calibrator you need.
The Fluke 787 ProcessMeterT puts a complete troubleshooting solution in the palm of your hand. Get in touch with more information, faster and easier with the newest member of the Fluke 80 Series, the 787 ProcessMeter. The 787 gives you the measurement capabilities you expect from our rugged, reliable DMMs plus the ability to source, simulate, or measure dc current with 1 microamp resolution and accuracy of 0.05%. Put it all together and you have the ideal tool for troubleshooting and calibrating current loop applications. So if you're tired of always tracking down a calibrator, lugging around two tools and switching back and forth, get the single best solution for doubling your power. The 787 ProcessMeter from Fluke.

DMM and loop calibrator in one tool
Precision 1000V, 440 mA digital multimeter
Measure ac and dc volts, ac and dc current, resistance, continuity, and frequency
0.1% dc voltage accuracy
0.05% dc current accuracy, 1 ‘A resolution to 30 mA
Simultaneous mA and % of scale readout
True rms ac voltage measurement to 1 kHz
Frequency measurement to 20 kHz
Min/Max/Average/TouchHold/Relative modes
Diode test and continuity beeper
DC current source/loop calibrator
20 mA current source/simulator
Simultaneous mA and % of scale readout
Manual step (25%, coarse, fine) plus auto step and auto ramp
Clear LCD with backlight; 4,000 counts (30,000 counts for dc current)
Externally accessible battery for easy battery changes
1000V overload protection on V, ohms, frequency
150V overload protection on mA, backed-up by 440 mA 1000V fuse
Designed to meet 1000 volt IEC 1010 Cat III standards

Technical Data

DC Current Output (Internal battery operation) Range and Resolution
0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up). Over-range to 24.000 mA

Drive Capability
12 V compliance, or 500 ohms @20 mA

Accuracy (% of span)
0.05 %

DC Current Simulate (External 24 volt loop supply) Range and Resolution
0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up). Over-range to 24.000 mA

Drive Capability
1000 ohms @20 mA

Accuracy (% of span)
0.05 %

Current Adjustment Modes Range and Resolution
Manual: Coarse Fine: 25% step
Automatic: Slow Ramp, Fast Ramp, 25% step

Measurement Accuracy

VDC Range and Resolution:
400.0 mV, 4.000V, 40.00V, 400.0V, 1000V

Best Accuracy (% of reading + LSD):
0.1% + 1

VAC (true RMS)
to 1 kHz * Range and Resolution:
400.0 mV, 4.000V, 40.00V, 400.0V, 1000V

Best Accuracy (% of reading + LSD):
0.7% + 2

mA DC Range and Resolution:
30.000 mA

Best Accuracy (% of reading + LSD:
0.05% + 2

A DC Range and Resolution:
1.000 A (0.440 A continuous)

Best Accuracy (% of reading + LSD):
0.2% + 2

A AC Range and Resolution:
1.000 A (0.440 A continuous)

Best Accuracy (% of reading + LSD):
1% + 2

Resistance Range and Resolution:
400.0 Ohms, 4.000 kOhms, 40.00 kOhms, 400.0 kOhms, 4.000 MOhms, 40.00MOhms

Best Accuracy (% of reading + LSD):
0.2% + 1

Frequency (0.5 Hz to 20 kHz) Range and Resolution:
199.99 Hz, 1999.9 Hz, 19.999 kHz, 199.99 kHz

Best Accuracy (% of reading + LSD):
0.005% + 1

Diode Test Range and Resolution:
2.400 V (measures diode voltage drop)

Best Accuracy (% of reading + LSD):
2% + 1

Continuity Range and Resolution
Beeps for resistance < approx. 100 ohms
*For measurement of adjustable speed motor drive output, consider the
Fluke 39, 41 or 43 power quality analyzers.


General Specifications

Maximum voltage applied between any jack and Earth Ground 1000 V rms
Storage Temperature -40 ºC to 60 ºC
Operating Temperature -20 ºC to 55 ºC
Temperature Coefficient 0.05 x (specified accuracy) per ºC (for temperatures < 18 ºC or > 28 ºC)
Relative Humidity 95% up to 30 ºC; 75% up to 40 ºC; 45% up to 50 ºC; 35% up to 55 ºC
Vibration Random, 2g, 5-500 Hz
Shock 1 meter drop test
Safety Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 Overvoltage Category III
Size 32 mm H x 87 mm W x 187 mm L (1.25 in H x 3.41 in W x 7.35 in L)
Size, with holster and Flex-Stand 52 mm H x 98 mm W x 201 mm L (2.06 in H x 3.86 in W x 7.93 in L)
Weight 369 g (13 oz); with holster and Flex-Stand 638 g (22.5 oz)
Battery Single 9V Alkaline battery (ANSI/NEDA 1604A or IEC 6LR61)
Battery Life 50 hours typical (measurement), 12 hours typical (sourcing 12 mA)
Warranty 3 years

Accessories

Please Call

Model

Fluke 787 ProcessMeter
Product ships with C81Y Protective Yellow Holster with Flex-Stand™, TL75 Safety-Designed Test lead Set plus AC70A Alligator Clips, one 9V alkaline battery (installed), Users Manual and Quick Reference Guide

Please select from the drop down menu below
Base price : US$595.00
Model :
Unit Price:
Quantity:

© 2006 Omni Controls, Inc.. All Rights Reserved.

Email: Sales@Omnicontrols.com
We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers