CATEGORY Datalogging and Printing Thermometers MAIN MENU ....................................... |
...... |
Catalog:Datalogging and Printing Thermometers
Dickson Data Loggers with Digital Display Temperature SM101 - Temperature Data Logger with Digital Display - From $199 Features: Dickson Digital Display Loggers will most likely tell you everything you need to know without downloading the data. With the large digital display (viewable from 25') and keypad you'll know the current readings, at the touch of a button you will see what the minimum and maximum readings have been. When you do choose to download the data user friendly DicksonWare software creates a graph of your data in seconds. DicksonWare features include complete customization of your graph, zooming, and viewing your data in tabular format. You can also view data from several loggers on a single graph enabling easy comparison of multiple sets of data. Transferring the data into documents or spreadsheets is a snap! Specifications: Internal Temperature Range (SM101/SM150): -30 to +122°F, -34 to +50°C Temperature Sensor: Thermistor Temperature Accuracy: ±1.8°F External Temperature Range - K-Thermocouple Probe (SM150/SM175): -300 to 2000°F (-184 to 1093°C)Optional Probe Required (D608); Range with standard bead wire probe: -300 to 400°F (-184 to 204°C) External Temperature Sensor (SM150/SM175): 4' Teflon coated K-thermocouple bead wire probe with mini-connector External Temperature Accuracy (SM150/SM175): Probe: ±7.9°F; Logger Only: ±1.8°F Data Capacity: 16,128 sample points (8,064 per channel) Sample Interval: Records data in configurable 10 second to 24 hour intervals, in 10 second increments Download Time: Approximately 1.5 minutes maximum Display Resolution: 1° resolution to 999.9; 1° resolution above 1000 Response Time: SM101: 12 min. to move 63% Full Scale; SM150/SM175: 1 min to move 63% Full Scale Power Source: 9V battery with 1 year battery life (typical at a 5 minute sampling rate @ 70 °F) or 120V AC adapter (adapter not included) Memory: Non-volatile (retains data even when battery is removed) Ambient Operating Temperature: -30 to +122°F (-34 to +50°C), 0 to 95% RH (non-condensing) Approvals: CE Calibration: User: Zero Pt.; Factory: Zero Pt. and Span Display: LCD, 4 Digit Dimension: 5 3/8" W x 4 1/2" H x 1 7/16" D (134.4mm x 114.3mm x 36.8mm) Enclosure: ABS Includes: 9V battery A015 - DicksonWare & Download Cable Specifications Software: Microsoft 95, 98, 2000 and NT compatible PC Requirements: PC w/386 or better micro processor, 4M RAM, 1 free COM (Serial) port, CD drive Version Required (Minimum): 1.00.00.35 Cable Type/Length: 9 pin male D-shell to male 2.5mm sterio plug, 6 feet long Computer Interface: RS-232 COM (Serial) port Note: A015 required with purchase of SM101, SM150 or SM175 Huge digital display's (.9" numerals) with minimum and maximum displayed at the touch of a button 9V Battery operation - 1 year battery life Stores 16,128 Sample points Temperature Range: -30 to +120°F These units feature our newest presentation software - DicksonWare Real time monitoring and graphing Faster downloads Makes exporting to other software a snap! AVAILABLE: EXTREEME TEMPERATURE RANGE (-300 TO 2000°F) K-THERMOCOUPLE PROBE - 2 CHANNEL LOGGERS (MODEL SM150 & SM175) SM150 Available With Optional D164 Probe The SM150 is the first Dickson Data Logger with a K-Thermocouple Probe K Thermocouple probe gives the SM150 unit powerful flexibility Wide temperature monitoring range of -300 to +2000°F Real time monitoring and graphing Uses DicksonWare Logger Presentation Software Specifications (summary)-SM150: Internal Temperature Range: -30 to +122°F, -34 to +50°C External Temperature Range - K Probe: -300 to +2000°F, -184 to +815°C Data Capacity: Single channel operation: 16,128 sample points; Dual channel operation: 8,064 sample points (each channel) Sample Interval: Records data in configurable 10 second to 24 hour intervals SM175 Available With Standard Bead Wire Probes The SM175 is the first Dickson Data Logger with 2 K-Thermocouple Probes K-Thermocouple probes give the SM175 powerful flexibility Wide temperature monitoring range of -300 to +2000°F Real time monitoring and graphing Uses DicksonWare Logger Presentation Software Specifications (summary) SM175: External Temperature Range - K Probe: With standard bead wire probe: -300 to +400°F, -184 to +204°C; With optional D164 high temp probe: -300 to +2000°F, -184 to +1093°C Data Capacity: Single channel operation: 16,128 sample points; Dual channel operation: 8,064 sample points (each channel) Sample Interval: Records data in configurable 10 second to 24 hour intervals Accessories A015 Data Logger Software & Download Cable $59 Notes: Required for downloading data A202 100' Straight Extension Cable $150 A708 Carrying Case $30 A712 Locking Wall Mount Case $40 D164 6" Stainless Steel Basic Probe (316SS), 4' Leadwire, +1650°F, +900°C $90 D605 4" Piercing Probe, 5' Coiled Cord, +1650°F, +900°C $50 D606 Angeled Surface Probe, 5' Coiled Cord, +1200°F, +649°C $100 D608 5" Immersion Probe, 5' Coiled Cord, +1650°F, +900°C $60 D617 10' Straight Extension Cable $35 E100 One Year Extended Warranty $59 N100 1-Point NIST Traceable Calibration $99 N300 3-Point NIST Traceable Calibration $149 N400 A2LA Accredited Calibration 3-pt. $259 N520 Certificate of Validation $29 R157 AC Adapter (recommended for continous display) $25 SW400 Logger Calibration Software $149 X025 25' Extension Cable (for remote connection of SM150 to PC) $75 X050 50' Extension Cable (for remote connection of SM150 to PC) $85 Please call for any optional accessories not listed Models SM101 Temperature Data Logger with Digital Display $199 Notes: A015 must accompany the initial purchase of data logger in order to operate SM150 Dual Channel Extreme Temperature (-300 to 1500) K-Thermocouple Data Logger $299 Notes: A015 must accompany the initial purchase of data logger in order to operate A015 DicksonWare Software and Download Cable $59 Notes: Required with initial purchase of any SM Logger SM175 Extreme Temprature Data Logger with 2 K-Thermocouple Probe $350 Notes: A015 must accompany the initial purchase of data logger in order to operate Please select Model and additional accessories from the menu's below
|
|
© 2000 Omni Controls, Inc.. All Rights Reserved. |