CATEGORY Ground Resistance Testers 3-4 Pole MAIN MENU ....................................... |
...... |
Catalog:Ground Resistance Testers 3-4 Pole
Biddle Model DE2/2 High Sensitivity Ground/Earth RT Cat-250202 Description Click here to view full-pdf specification sheets MEGGER DET2/2 Accurately measures ground resistance under the most demanding conditions High resolution - 0.001 W, with autoranging Simple menu driven operation The DET2/2 digital ground resistance tester provides a wide resistance range from 0.010 W to 19.99 kilohms for testing larger or more complex grounding systems and for difficult testing environments, with ±0.5% accuracy and 0.001 W resolution. Microprocessor control and advanced filtering simplify testing in environments with high levels of interference. Applications The DET2/2 Earth Tester is a reliable instrument designed for larger or more complex earthing systems, including communications earthing systems and difficult testing environments. It may be used to test in accordance with BS 7430 (1991), the IEE Wiring Regulations and VDE 0413 part 7 (1982). The instrument is suitable for soil resistivity measurements, which are used to establish the optimum electrode design and site, as well as perform archeological and geological investi-gations. Resistivity tests assist in the design of a correct earth system and avoid the cost of re-working electrode installations. Earth testing kits, which include suitable test spikes and test leads, are available separately. Features • High resolution – 1 m½ – ideal for large earthing systems • High accuracy for earth electrode and soil resistivity testing • Test voltage 50 V max. for safety • Rechargeable battery power with long battery life and rapid re-charge • A robust, versatile instrument with IP54 protection • Filter and high current features to enable valid earth testing in difficult situations Specifications Please see pdf. for more detailed specifications Earth Resistance Range 0,010 ½ to 19,99 k½ (auto-ranging), 1 m½ resolution. Accuracy (23 °C = 2 °C) ±0,5% of reading ± 2 digits Service Error ±5% of reading ± 2 digits ± 10 m½ (meets VDE service error over 50 m½) Comply with Standards BS 7430 (1991) VDE 0413 Part 7 (1982) Test Frequency 105 to 160 Hz reversing d.c. (50 Hz operation default to 128 Hz, 60 Hz operation default to 150 Hz) Set in steps of 0,5 Hz Test Current 50 mA max (selectable high and low levels) Maximum Output Voltage < 50 V r.m.s. Ordering Details Auto Earth Tester DET2/2 Included Accessories Mains supply lead for battery charging Operating instruction book Optional Accessories ![]() Click here to purchase accessories Please call 1800 783 6664 for any items not listed Model Auto Earth Tester DET2/2 Please order from the menu below
|
|
© 2000 Omni Controls, Inc.. All Rights Reserved. |