Item category
Electrical Appliance Test Equip / High Pot/ Ratiometer
Home
View Cart
Order Info
  Biddle MEGGER MHP1 and MHP2 HiPots

Description

Click here to view full-pdf specification sheets

Conform to UL testing specifications
Meet 120 kW requirement for sensitivity
Test voltage starts at zero crossing
Transient free voltage
Press to test or toggle ON/OFF
Calibrated trip settings
Three fail modes
Breakdown only
Excessive leakage only
Breakdown or excessive leakage
Optional remote on/off switch
Provision for safety interlocks

Megger MHP1 and MHP2 HiPots are designed for workshop and production testing of electrical items. The MHP1 has an ac output voltage while the MHP2 offers both ac and dc outputs.

Both instruments are compact and portable so that they may be easily moved to the item that needs testing.

Features

• Test voltage starts at zero crossing.
• Transient free voltage.
• Press to test or toggle ON / OFF.
• Calibrated trip settings.
• Three fail modes
• Breakdown only
• Excessive leakage only
• Breakdown or excessive leakage
• Optional remote on / off switch.
• Provision for safety interlocks.
• Outputs for external fail indication
• Output for “High voltage on” beacon.

Specifications

Please see pdf. for more detailed specifications

Test Voltage
MHP1 0-3kV a.c. continuously variable
MHP2 0-3kV a.c. and 0-4kV d.c. continuously
variable

Ripple Content on d.c. range.
<150 V. a.c. peak to peak at 1 mA.

Current trip settings
0.3, 0.5, 1.0, 2.0, 3.5, 5.0, 10.0 mA. Peak or d.c.

Current trip accuracy
±5% of indicated value.

Display
Voltage - Analogue Movement
60 mm. (2.36”) scale length

Display Accuracy
±2.5% of full-scale deflection

Features

Remote switch:
5-pin DIN connector on rear of instrument allows connection of remote voltage ON/OFF switch (see optional accessories)

Safety interlocks:
Provision on rear of instrument for wiring safety interlocks Beacon: Provision on rear of instrument to wire in a “Voltage ON” warning beacon. Maximum current available 0.5A at supply voltage

Pass/Fail indicator:
Normally open/normally closed terminals available to
power external indicator. Max rating 8A at 250 V a.c.

Power Supply
230 or 115 V a.c. 50/60Hz depending on model.
Safety

Meets the requirements of IEC 1010-1 (1995) and EN
61010-1 (1995)

Fuses
2x T2A HBC 32 x 6.5 mm (11/ 4 ” x1/ 4 ”)
Power cord (where applicable): 3A fuse to BS1362.

EMC
Meets the requirements of EN50081-1, EN50082-1 (1992)
and EN61326-1 (1998).

Temperature
Operating 0°C to 40°C (32°F to 104°F)
Storage -20°C to 60°C (32°F to 140°F)

Humidity
Operating 80% RH at 40°C (104°F)

Dimensions
257 x 280 x 110 mm. (11 x 11 1/ 2 x 4 3/ 4 inches)

Weight
8 kg. (17.6lb.)

Cleaning
Wipe disconnected instrument with a clean cloth dampened with soapy water or Isopropyl Alcohol (IPA)

Ordering Details

a.c. Hipot (230V, UK plug) MHP1 UK230
a.c. Hipot (230V, Schuko plug) MHP1 EUR230
a.c. Hipot (115V, US plug) MHP1 US115
a.c./d.c. Hipot (230V, UK plug) MHP2 UK230
a.c./d.c. Hipot (230V, Schuko plug) MHP2 EUR230
a.c./d.c. Hipot (115V, US plug) MHP2 US115

Please call for international versions

Included Accessories

User Guide 6172-314
Low return lead 6220-309
4kV High Voltage probe 5310-406
Mains power Cord (UK230) 25970-028
Mains power Cord (EUR230) 6180-334
Mains power Cord (US115) 25970-002

Optional Accessories

High Voltage Gun Probe 6420-061
Remote On/Off switch 6220-641
Warning beacon 6121-446
120 kohm resistor 6121-447

Please call 1800 783 6664 for any items not listed

Model

MHP-1 AC, 0-3 kV ac, 0.3-10mA, Cat-MHP-1
MHP-2 AC/DC, 0-4 kV ac , 0-3 kV dc, 0.3-10A,
230315 AC 0-3 kV ac, 0.3-12mA, Cat-MHP-1
230415 AC 0-4 kV ac, 0.3-12mA, Cat-MHP-1
230425 AC/DC 0-4 kV ac 0-5 kV dc, AC 0.3-12mA, DC 0.43-17mA,

Please order from the menu below
Base price : US$1,600.00
Model :
Unit Price:
Quantity:

© 2006 Omni Controls, Inc.. All Rights Reserved.

Email: Sales@Omnicontrols.com
We guarantee a 24 hour response on all inquiries made via email.
For quicker response please call Omni Controls
at any of the above numbers