Item category Conductivity TDS Testers Monitor Controller\Transmitter
|
|
Oakton CON 510 Benchtop Meter
An affordable way to take consistent, accurate conductivity or TDS
measurements in your laboratory!
|
Dual display shows both conductivity or TDS and temperature in °C or °F
Single- and multi-point
automatic or manual calibration: customize meter calibration for quick
checks or for best meter accuracy
Auto ranging across five
ranges: offers the best resolution for your measurements
Advanced set up mode:
recalls previous calibration data, conductivity/TDS effective cell
constants per range, and more
Built-in non-volatile
memory: stores up to 50 conductivity or TDS readings with corresponding
temperature
Automatic or manual
temperature compensation
Selectable cell constant
Adjustable conductivity
to TDS conversion factor and temperature coefficient: gives highest
accuracy in any solution
Selectable normalization
temperature: choose between 15°C and 20°C
Built-in electrode
holder arm; selectable "Ready" indicator; Hold function;
diagnostic error messages
Includes WD-35608-50
conductivity cell
| Measures |
Conductivity, TDS, °C, °F |
| ConductivityRange |
0 to 19.99
0 to 199.9
0 to 1999 µS
0 to 19.99 mS
0 to 199.9 mS |
| ConductivityResolution |
0.01 µS
0.1 µS
1 µS
0.01 mS
0.1 mS |
| ConductivityAccuracy |
±1% full scale or ±1 digit |
| ConductivityCalibration |
Automatic: single or multi-point up to 4 points
(84 µS,1413 µS, 12.88 mS, 111.8 mS)
Manual: single or multi-point up to 5 points (one user
selectable point per range for multi-point calibration) |
| TDSRange |
0.00 to 9.99 ppm
10.0 to 99.9 ppm
100 to 999 ppm
1.00 to 9.99 ppt
10.0 to 99.9 ppt
100 to 200 ppt |
| TDSResolution |
0.01 ppm
0.1 ppm
1 ppm
0.01 ppt
0.1 ppt |
| TDSAccuracy |
±1% full scale or ±1 digit |
| TDSCalibration |
Automatic: single or multi-point up to 4 points
(84µS, 1413µS, 12.88mS, 111.8mS)
Manual: single or multi-point up to 5 points (one user
selectable point per range for multi-point calibration) |
| TemperatureRange |
0.0 to 100.0°C
32 to 212.0°F |
| TemperatureResolution |
0.1°C or °F |
| TemperatureAccuracy |
±0.5°C or ±0.9°F |
| TemperatureCalibration |
offset 0.1° increments up to ±5° |
| Memory |
up to 50 sets with temp |
| Cell constant |
selectable 0.1, 1.0, 10 |
| Temperature coefficient |
adjustable from 0 to 10% per °C or °F |
| Dimensions |
9"W x 2-3/8"H x 7"D |
| Shipping weight |
meter only 1.25 lbs. (0.6 kg); boxed 3 lbs (1.4
kg) |
| |
© 2000 Omni Controls, Inc.. All Rights Reserved.
|