Large dual LCD shows both pH (or mV) and temperature
Two set point, two SPDT
relay operation- choose from lo/lo, lo/hi, hi/lo or hi/hi control
Separate alarm relay
0 to 2000 second time
delay adjustment on all relays
Separately adjustable
high and low set point hysteresis bands
0-20/4-20 mA
transmitter/recorder output
Push button two-point
calibration
On-line electrode offset
adjustment
Hold feature lets you
connect flow or level switches to protect your pump
Two level password
protection
LED indicators signal
control activities
Battery back-up of
memory
OAKTON is proud to present our highly versatile 1000 series pH/ORP
controller. Select from three control types. Use on/off control to shut
off your pump or valve when your process passes its set points. Use
pulse frequency or pulse length proportional control to gradually
increase or decrease your pump’s or valve’s response, depending on
the amount by which your process has passed the set point.
Customize your controller to fit your exact application! This unit is
selectable for pH or ORP (as mV or percent) control; 0-20 or 4-20 mA
scaleable, isolated recorder output; normally open or closed relays; and
manual or automatic temperature compensation. Controller also features a
safety Hold function, manual override of the relays, and resistance to
electrical signal input noise.
Click below to download Acrobat (.pdf)
file of:
pH
1000 controller product bulletin
pH
1000 controller manual
| Measures |
pH, mV, °C |
| pHRange |
0.00 to 14.00 pH |
| pHResolution |
0.01 pH |
| pHAccuracy |
±0.01 pH |
| pHCalibration |
one or two points (select from pH 1.00, 4.00,
7.00, 9.00, 10.00) |
| mVRange |
±1000 mV |
| mVResolution |
1 mV |
| mVAccuracy |
±1 mV |
| mVCalibration |
offset for ORP mV calibration, or two points (20%
and 80%) for ORP % calibration |
| TemperatureRange |
-9.9 to 125°C |
| TemperatureResolution |
0.1°C |
| TemperatureAccuracy |
±0.1°C |
| TemperatureCalibration |
offset up to ±5°C |
| Control type |
on/off or proportional (selectable) |
| Number of inputs |
one |
| Number of set points |
two (high and low) |
| Separate alarm relay |
yes |
| OutputControl |
2 SPDT relays, 6 A at 110 VAC, 250 VAC maximum |
| OutputAlarm |
1 SPDT relay, 6 A at 110 VAC, 250 VAC maximum |
| OutputPulse |
pulse length (0.5 to 20 sec) or pulse frequency
(60 to 120 pulses per min) |
| OutputCurrent |
isolated 0-20.4-20 mA, with 20% to 100%
full-scale scalable boundaries, 600 W
maximum load |
| Hysteresis |
0.1 to 1.0 pH, 10 to 100 mV, or 1 to 10% |
| Relay delay |
selectable, 0 to 2000 seconds |
| Input impedance |
10^12 MW |
| Electrical isolation |
yes, galvanically |
| Temperature Sensor |
100 W or 1000 W
Pt RTD |
| Temperature Compensation |
Automatic or manual from -9.9 to 125°C |
| Password protection |
two level password |
| Display |
dual line LCD, 4-digit upper and 3 1/2 digit
lower |
| Operating Temperature |
-10 to 60°C |
| Housing |
1/4 DIN |
| Dimensions |
3.8" x 3.8" x 6.9" (9.6 x 9.6 x
17.5 cm) |
| Shipping weight |
2.5 lbs (1.2 kg) |
|