CATEGORY Current / Voltage Loggers / Power MAIN MENU ....................................... |
...... |
Catalog:Current / Voltage Loggers / Power
AEMC PQL 100 Power Meters & Loggers Features The PQL 100 Series is a single phase Power Quality Logger designed to measure and log from a complete suite of electrical and power quality parameters. It is accompanied by an easy-to-use report compliant software package. Portable, compact unit - plugs into standard US 120V outlets Simple operation: Plug in, Record, Download & Read Measures and stores electrical parameters: V, A, Hz & more Measures and stores power parameters: W, VA, Var, Demand, Peak Demand & more Measures and stores power quality parameters: Harmonics, THD (rms & fundamental), K-factor & more Automatically captures worstcase Surge, Sag & THD waveforms High accuracy & resolution: 128 samples/cycle, 16 bit resolution LEDs indicate mode of operation Records up to 12 data channels Powered from voltage input channel Battery backup data integrity during power outages and programmed configuration for up to 1 year Optically isolated RS-232 output for direct connection to a PC IEC 1010, 150V, Cat. III Includes DataView Lite Analysis & Reporting Software Applications: Monitor power quality in North American commercial, industrial and residential application Monitor power quality at computer workstations Monitor power quality on laboratory equipment Specifications Electrical Specifications Voltage Range 0 to 140V Resolution 0.1V Accuracy ±(0.3% of Reading + 0.3V) Current Range 0 to 15A (70A peak maximum) Resolution 0.01A Accuracy ±(0.5% of Reading + 0.03A) @ 0.75A to 15A; ±0.30A @ < 0.75A Frequency Range 45 to 65Hz Resolution 0.01Hz Accuracy 0.1Hz Programmable Parameters RMS, Min. & Max of the following parameters: Voltage, Current, Frequency, Even Voltage Real Power (W), Reactive Power (Var) and Apparent Power (VA) Total Harmonic Distortion for Voltage and Current (IEEE or IEC Definition)(See Automatic Storage) Power Factor (Total and Displacement) K-Factor Demand 10/15/30 minutes or user-definable Peak Demand Over demand period Voltage Sag User-definable magnitude (See Automatic Storage) Voltage Surge User-definable magnitude (See Automatic Storage) Input Input Channels 1 Voltage / 1 Current Sample Rate 128 per cycle per channel Recording Storage Rate 125ms to 7 days Recording Session Length 15 minutes to 8 weeks selectable from table or user programmable Total Memory 128KB (64,000 records maximum) Date and Time MM/DD/YY hh/mm/ss.sss Automatic Storage Five worst-case THD waveforms for each for Voltage and Current: One per 1/5 of recording session length Five worst surge (duration X magnitude) & sag occurrences are automatically recorded in high-resolution mode (RMS value of each cycle is recorded for 128 cycles at the entry and 128 cycles at the exit of the surge/sag) regardless of the storage rate selected. One waveform per each occurrence of the worst-case surge/sag with the worst THD is stored. A table for the 100 worst-case occurrences of the surge/sag is maintained. The table stores time & date, duration & magnitude of each surge/sag including the high-resolution mode surge/sag. In addition, an Event Counter is maintained for all occurrences of the surge/sag. Operation Indicators Red: Solid on when AC voltage is present Yellow: Solid on when data stored in memory. Single blinks when memory is full Green: Single blinks when the logger is in Standby mode. Double blinks when the logger is in Recording mode Controls Record Start/Stop Reset Power Supply Power Supply 75V to 140V @ 45Hz to 65Hz Battery Internal NiCD rechargeable battery-pack which continuously charges from the power line. Provide 30 minutes of ride-through in case of power loss during recording and provides 1 year of memory backup when fully charged Internal Li battery for additional memory backup up to 1 month Unit is powered from the power line in normal operation. Serial Interface Output RS-232 via DB9 connector Isolation Optically isolated. 2500V maximum Baud Rate 9600, 19.2K. Selectable from DataView Mechanical Specifications Material: UL94V-0 polycarbonate (ABS) Dimensions: 5.91 x 3.15 x 2.36" (150 x 80 x 60mm) Weight: 1lb 7oz (650g) including the batteries Environmental Specification Operating Temperature: 14° to 122°F (-10° to 50°C) Storage Temperature: -4° to 140°F (-20° to 60°C) Relative Humidity: 0% to 85% @95°F (35°C), non-condensing Safety / Reference Specifications Safety: IEC 1010-1, 150V, Pollution Degree 2, Cat. III Accessories Please call 1800 783 6664 Model AEMC PQL 100 Power Meters & Loggers Please select from the drop down menu below
|
|
© 2000 Omni Controls, Inc.. All Rights Reserved. |