Amprobe AT-2000 SERIES Advanced Tracers


Features

Designed to handle the majority of tracing applications, the AT-2000 series of Advanced Tracers combine 15 years of experience and three different technologies into one multi- purpose instrument. Economically priced, fully portable and easy to use, the AT-2000 series has the following capabilities:

5 models to choose from
Trace live conductors buried up to 13 feet.
Trace and identify load-side equipment from the circuit breaker while energized.
Trace line-side wiring without power interruption on circuits from 9 to 600 volts AC or DC
Trace open wires for over a mile
Trace wire in conduit or, even the conduit itself
Locate ground faults and shorts
Identify individual wires in a bundle
All units are fully fused protected and intrinsically safe.

AT-2005 Shown
Includes the R2000 receiver, S2600 load signal generator, T2200 trans- mitter, A2201 clamp, C2901 and C2902 cordsets, AD-1 adapter, B2024 battery booster, B2025 recharger/converter, and Instruction Book P/N 937775.

FEATURES - AT-2001
Includes the R2000 Receiver, S2300 Load Signal Generator (9-300V AC/DC), C2901, C2902 Cordsets, AD-1 Adaptor and Manual

FEATURES - AT-2002
Includes the R2000 Receiver, S2600 Load Signal Generator (9-600V AC/DC), C2901, C2902 Cordsets, AD-1 Adaptor and Manual

FEATURES - AT-2003
Includes the R2000 Receiver, T2200 Transmitter C2902 Cordset, AD-1 Adaptor and Manual

FEATURES - AT-2004
Includes the R2000 Receiver, S2600 Load Signal Generator (9-600V AC/DC) T2200 Transmitter, C2902 & C2901 Cordset, AD-1 Adaptor, A2201 clamp, manual.


Specificationsand Accessories


ATGC-1 AT-2000 Ground Coil™ Accessory

• Trace and locate buried conductors like Highway Lighting Conductors, Main
Electrical Feeds, Water Mains, Gas Mains, and Telephone Lines
• Low Cost
• Eliminates Direct Connection of Transmitter
• No access to the conductor required


B2024 BATTERY BOOSTER

24 V Nicad rechargeable battery for the T2200, will triple its output. For use on runs over one mile or when using the A2201 on runs over 200 ft. The B2025 recharger works in conjuction with the B2024.

Weight: 19 oz.

Fuse: Internal self resetting


B2025 RECHARGER/CONVERTER

115VAC/24VDC Converter can be used to recharge the B2024 (allow 8 hours) or directly boost the T2200.


Note: The AT series is covered by one or more U.S. patents; 5,413,499; D356,039; D355,618; D355,619; 5,338,228. Other U.S. & foreign patents pending.


The R2000 RECEIVER has two detectors in its tip which are tuned to pick up the electro-
magnetic signals (‘short’ mode) or electrostatic signals (‘open’ mode) generated by the
other components. The LED’s and sensitivity settings indicate the relative signal strength to allow easy detection of the signal source. The R2000 is included in each of the five systems:
AT-2001 through AT-2005.

R2000 Receiver
Detectors: Electromagnetic coil pickup for short mode. Electrostatic plate pickup for open mode
pick-up for open mode
Sensitivity Selection: x1, x10, x100 coarse gain adjustment; 0-10 fine adjustment
Short Mode Performance: Over 20’ in air under test conditions.
Open Mode Performance: Over 12’ in air
under test conditions
60 Hz Rejection: 120dB
Power Source: 9V alkaline battery (Amprobe model
MN-1604)
Display: 10 LED’s with chroma filter lens
Case: Flame Retardant ABS 911

Note: The AT series is covered by one or more U.S. patents; 5,413,499; D356,039; D355,618; D355,619; 5,338,228. Other U.S. & foreign patents pending.

The LOAD SIGNAL GENERATORS S2300 & S2600, when connected to an energized line, will draw a rapidly fluctuating current pulse from the source, causing the power line to emit an electromagnetic signal which is detected by the R2000 Receiver in the ‘short’ mode. These devices allow tracing
of line-side conductors without power
interruption or interference. The S2300 will accept 9-300V AC or DC and comes with the AT-2001. The S2600 accepts 9-600V AC or DC and comes with the AT-2002, 2004, and AT-2005.

S2300 Operating Voltage:
9-300 volts AC or DC
S2600 Operating Voltage:
9-600 volts AC or DC
Operating Frequency: 32.768 KHz
Duty Cycle: Transmits 2 pulses with a
duration of 0.0625 sec. each every 0.5 second
Current Output -
Low Mode: 35mA peak, 4mA average
High Mode:70mA peak, 6mA average
S2300 Fuse: Fast acting 250mA @380V
(6mm x 32 mm)
Cat. no. 380.25-6X32
S2600 Fuse: Fast acting 250mA @660V
(6mm x 32 mm)
Cat. no. 660.25-6X32
Case: Flame retardant ABS 911

The T2200 TRANSMITTER injects a signal into an unenergized conductor. If the conductor is broken (open), no current will flow, so the signal is present as a voltage pulse, which is detected along the conductor’s length by the R2000’s electrostatic detector (‘open mode’). The signal will stop at the open. The T2200 comes with the AT-2003, AT-2004, and AT-2005

T2200 Transmitter
Operating Frequency: 32.768 KHz
Duty Cycle: Transmits 2 pulses with a
duration of 0.0635 sec. each every 0.5 seconds.
Signal Output: 9V Supply 24 V Supply
High Setting: 1A, 31V 3A, 105V
Medium Setting: 1.8A, 13V 6A, 45V
Low Setting: 3.0A, 6.5V 10A, 22V
Fuse: Fast acting 2A @250V 3AG .25" x 1.5"
Cat no. 2502-6X32
Battery: 9V alkaline (Amprobe Model
MN-1604), 24V jack will accept battery pack accessory (B2024 or B2025)
Case: Flame retardant ABS911

When the A2201 INDUCTIVE CLAMP is clamped around an energized line with
current flowingand plugged into the T2200 Transmitter, it will induce a signal onto the downstream (load) side to enable identification of equipment on that circuit. The A2201 comes with the AT-2004 and AT-2005.

A2201 Clamp-on Transmitter Accessory
Operating Frequency: 32.768 KHz as supplied by the T2200
Case Breakdown Voltage: 3000 Volts
Maximum Wiresize: 2000 MCM or 2" dia. cable
Battery: None, power is supplied by T2200

General
Operating Temperature: 0 to 120°F
Storage Temperature: -40 to 150°F
Case Material: ABS
Case Size: 11" x 15.5" x 4" (39.4x27.9x10.2 cm)

FOR ACCESSORIES PLEASE CALL

Model

AT-2005
Includes the R2000 receiver, S2600 load signal generator, T2200 trans- mitter, A2201 clamp, C2901 and C2902 cordsets, AD-1 adapter, B2024 battery booster, B2025 recharger/converter, and Instruction Book P/N 937775.

AT-2001
Includes the R2000 Receiver, S2300 Load Signal Generator (9-300V AC/DC), C2901, C2902 Cordsets, AD-1 Adaptor and Manual

AT-2002
Includes the R2000 Receiver, S2600 Load Signal Generator (9-600V AC/DC), C2901, C2902 Cordsets, AD-1 Adaptor and Manual

AT-2003
Includes the R2000 Receiver, T2200 Transmitter C2902 Cordset, AD-1 Adaptor and Manual

AT-2004
Includes the R2000 Receiver, S2600 Load Signal Generator (9-600V AC/DC) T2200 Transmitter, C2902 & C2901 Cordset, AD-1 Adaptor, A2201 clamp, manual.


Please select from the menu below
Base price : US$577.00
Model :
Unit Price:
Quantity: