CATEGORY
MAIN MENU |
![]() Features Mirror scale High impact molded case, fully-insulated Self-locking meter stand handle All-weather test leads Recessed glass window reduces possibility of scratches and static electricity build-up All ranges are fuse protected or can withstand the momentary misapplication of 220 volts maximum. Specifications MODEL AM-3E IS SUPPLIED WITH MTL-2 ALL-WEATHER TEST LEADS AND MTC-3 ALLIGATOR CLIP ADAPTORS. ALL OTHER ACCESSORIES AVAILABLE SEPARATELY. Voltage Ranges: AC 0-30 / 150 / 300 / 750 (10,000 ohms/V) DC 0-3 / 30 / 150 / 300 (100,000 ohms/V) 15KVAC and 15KV DC ranges can be added through us of HV-2 High Voltage Probe and HVR-3 (AC volts) or HVR-3D (DC volts) resistor. Resistance Ranges: 0-500 ohms with 5 ohms midscale 0-5,000 ohms with 50 ohms midscale 0-50,000 ohms with 500 ohms midscale 0-5 Megohms with 50,000 ohms midscale Current Ranges: DC - 0-10 µA 0-15/150 µA @ 300mV 0-1.5/150mA @ 300mV AC - 0-5/25/100/250 amps with accuracy current transducer A603 (60Hz) or A653 (50Hz) 0-0.5/2.5/10 amps with accuracy A603 or A653 and energizer A47-L. 0-50/1000/1200 amps with accuracy A603 or A653 and Deca-Tran® A50-1. 0-1250/5000/6000 amps with accuracy A603 or A653 and Amptran® CT50-1 or CT50-2 0-10/50/250/500 amps with accessory current transducer A703 (60Hz) or A753 (50Hz) 0-1 / 5 amps with A703 or A753 and energizer A47-L. 0-100/1200 amps with A703 or A753 and Deca-Tran® A50-1. 0-2500/6000 amps with A703 or A753 and Amptran® CT50-1 or CT50-2 Millivolt Ranges: 0-75/750 /1500mV DC at 10µA 0-300mV DC Temperature Ranges: Low: -10°F to + 250°F with probe RBT-11B or RBT-12B or RBT-13B (for non-corrosive applications). RBT-13B should not be used in temperatures above 150°F. High: + 70°F to + 1200°F with probe TC-3. Accuracy: DC: ±3% F.S. VAC: ±4% F.S. Amperes AC: ±5% F.S. Resistance: ±3% of arc Low Temperature: ±3% of Arc including probe High Temperature: ±3% of F.S. including probe Ohmmeter Power Supply: 2 "C" Alkaline batteries in parallel Circuit Protection: 1 #8AG361, 1 amp fast blow 1 #3AG312, 0.1 amp fast blow Do not use substitute fuses as resistance can vary Size: 5 1/4" x 7 1/2" x 3 1/4"d (13.34cm x 19.1cm x 8.26cm) Instrument Weight: 2 1/4 lbs. (1.02Kg) Temperature Probes: The range -10% to + 250°F is obtained by one of the temperature probes RBT-11B, RBT-12B or RBT-13B (all for non-corrosive applications only) which plug directly into the AM-3E. Lead length 12 feet (3.65m). The range of + 70° to + 1200°F is obtained by using TX-3 Thermocouple. Length 5 1/2 ft. (1.67m). Note: For earlier model AM-3, use temperature probes RBT-11, RBT-12, RBT-13. These probes will not fit model AM-3B or AM-3E. CARRYING CASES A choice of two rugged, ever-ready cases. The MM-3 provides storage space for the AM-3E and one or two accessories. The MM-4 is a two compartment case that accommodates the AM-3E, the test leads, a temperature probe, the TC-3 and the A603 or A703. Instruction Book: P/N 936752 MODEL TAM-3E TEST MASTER KIT This professional kit will satisfy the majority of your daily testing needs. Measure AC amps and volts, DC micro and mill-amps; DC millivolts and volts; Resistance; Temperature. Contains AM-3E Multimeter, A603. Clamp-on Current Transducer. RBT-12B Universal Temperature Probe and TC-3 Thermocouple in the Deluxe MM4 Carrying Case. A653 for 50Hz. (Specify). The TAM-3E has the same Voltage, Resistance, Millivolt, DC Current Ranges as model AM-3E, plus: AC 0-5 / 25 / 100 / 250 Amperes (with A603 60Hz or A653 50Hz) Temperature Ranges: -10°F to + 250°F (with RBT-12B in non-corrosive applications) + 70°F to + 1200°F (with TC-3). Accessories Please Call for accessories not included Model MODEL AM-3E Please select from the menu below © 2000 Omni Controls, Inc.. All Rights Reserved. |