CATEGORY
Data Chart Recorders (paperless)
MAIN MENU |
![]() Features You may not have to climb a mountain to get the job done, but whether you work indoors or outdoors, the DM-IITM gives you peak performance in any environment. The DM-IITM Data Logger/Recorder is the next step in chartless recording. The New DigiMaticTM II is an AC Data Logger/Recorder in a stand alone configuration. Data can be viewed in the field via its large self-contained backlit LCD display or can be accessed and downloaded through a personal computer. • Three DM-II™ versions: DM-II™ Standard Unit; DM-II™ CE CE Approved; DM-II™ NA UL Approved • Single or three phase capable • AC voltage 5 to 600 volts • AC current 1 to 1000 amperes • 3 Channels for voltage measurements and 4 channels for current measurements • Graphic display 160x160 pixel • All readings are True RMS • Power Measurements include: 1- Watts 3- VA 2- Vars 4- PF(Power Factor) • Energy Measurements include: 1- KW-HR’s 2-Demand or Non Demand • User selectable recording rates. • DM-II View™ software allows downloading data to a personal computer running Windows™ 3.11/95 and NT environment. Computer requirements: 486 - 50Mhz, 8Megs of RAM (16Meg recommended). • Line Operated (120V/60Hz & 240V/50Hz) • Battery backup protects memory if a power failure occurs and allows recording session to continue. • Auto Ranging • Real time clock • Multi Languages built in: 1- English 2- German 5- French 3- Spanish 4- Italian • Rugged ABS plastic case with a weather resistant design • Made in USA Specifications Inputs: Voltage - Three voltage channels with common (V1, V2, V3 and COM). The test leads are flexible straight sheath banana plugs on each end, rated 1000Vrms and a length of 6 feet (set of four supplied). The alligator clips have a 1 inch jaw opening and are rated at 10A max (set of four supplied). Current - Four current channels (I1, I2, I3, I4) DM-CT: 1 to 1000A ±1% of reading (four supplied) ACF3000: 30A to 300A ±1% of full scale 300A to 3000A ±1% of full scale Note: The ACF-3000 is an optional accessory. A total of three would be required for a 3Ø measurement. Adaptor ACF-5 is required. Ranges: AC Voltage measurements (True RMS) 5 to 600 Vrms. AC Current measurements (True RMS) 1 to 1000 Arms with four supplied DM-CT’s Accuracy: Voltage measurements ± 1% of reading +3 LSD's Current measurements ± 1% of reading +3 LSD's Voltage and Current Measurement Selections: True RMS voltage and current, RMS max, RMS min, RMS avg, Peak max ![]() Power measurement Capabilities: Real Power P (watts), Apparent Volt-amperes S (VA), Reactive Volt amperes Q (VAR), True Power Factor (tPF) Energy Measurement Capabilities: Kilowatt Hours (KWH), Demand (KW) Programmable Thresholds: User selectable high/low limits for RMS voltage and current. Recording Modes/Rates/Intervals: User selectable normal and loop (wrap around) recording modes. User selectable recording rates of 1 sec, 5 sec, 15 sec, 30 sec, 1 min, 5 min, 15 min, 30 min. Recording intervals for Demand (KW) are 15 min and 30 min. Memory: Total of 600K RAM memory. The recording session length depends on the recording rate, the number of selections, recording mode, and recording interval. The memory has a lithium battery backup to preserve its contents in the event of the absence of AC power and batteries. Real Time Clock: The user programmable real-time clock is displayed in 12/24 hour formats and HH:MM:SS Day month year, daylight savings option, accuracy ±1 min per month. System Configuration: Total of four presorted setup configurations for 1Ø and 3Ø systems: 1Ø 2W, 1Ø 3W, 3Ø 3W Straight Delta, and 3Ø 4W Wye. Note: Any or all parameters of a phase configuration can be recorded. PC Interface: Optically isolated RS-232 serial interface. DM-II View™ software for display, analysis, and report generation. User selectable baud rates of 9600, 19200 and 38400 baud. Power Requirements: AC line voltage with battery backup operation. The ON/OFF dual color LED indicates the unit’s power source - Green indicates AC line power and Red for battery backup power. Designed to Meet: UL3111-1, CE (LVD/EMC/EMI) Sample Rate: 130µ sec. (7.68 KHz, 128 samples per cycle per channel, total of 8 channels). Case: Material: Injection molded flame retardant ABS911, rugged, water-resistant, and corrosion proof. Case dimensions: 17.5” x 11.6” x 7.5” Weight: 16 lbs. (7.3 kgs.) includes batteries, 4 CTs, voltage leads and alligator clips. Pressure relief valve: Important - Be sure the knob located next to the handle is open when encountering atmospheric changes. Battery: 6 alkaline “D” cells (not supplied) Battery Life: 21 hours continuous with backlight OFF, 1 sec. recording rate, normal recording mode, all parameters selected for 3Ø 4W WYE configuration Operation Temperature Range: 32 to 122°F (0-50°C) RH<85% Storage Temperature Range: -4 to 140 °F (-2 to 60°C) RH<90% ![]() SYSTEM REQUIREMENTS FOR DM-II VIEW™ USER INTERFACE Windows™ 3.11/Windows™ 95 and Windows™ NT compatible 486-50DX or higher 8MB RAM minimum, 16MB recommended Hard disk requires 4.5MB for installation Full memory download of 600KB requires 9.6MB on hard drive Graphic Display: User adjustable contrast, LED backlight, 160x160 pixel, STN Switch Keypad: 15 key membrane switch keypad, shielding protection, embedded dual color red/green LED indicating power from line voltage or from batteries Accessories please call Test Leads & Alligator Clips (Set of 4)* DVL-2 Current Transducer (Black)* DM-CT-BK Current Transducer (Red)* DM-CT-R Current Transducer (Blue)* DM-CT-B Current Transducer (Yellow)* DM-CT-Y Output Lead* RS-232 Power Cord* PC-4 "DM-II View™ 3.5"" Discs (Set of 5)*" DISC-II DM-II View™ Instruction Manual PIN 995754 Flexible Current Transducer (3000 Amps)** ACF-3000 Adapter for Flexible Current Transducer . (BNC male to 2 Pin twist connector)** ACF-5 *Supplied **Optional Model DigiMaticTM II Please select from the menu below © 2000 Omni Controls, Inc.. All Rights Reserved. |