ScopeMeter 190 Series has specifications you'll typically find on high-end bench oscilloscopes. They offer 200 MHz, 2.5 GS/s real-time sampling and advanced memory and triggering functions. They're rugged, compact and battery powered.
The ScopeMeter 190 Series offers up to 200 MHz bandwidth for capturing high frequency signals found in today's state-of-the-art electronics. For less demanding applications, there's also a 100 MHz and a 60 MHz model. You still get the same advanced functionality without paying for the bandwidth you don't need.
Fast sampling to see what's really happening
With a maximum real-time sampling rate of 2.5 GS/s per input, you
can see what really happens with 400 p resolution. Both inputs have their own digitizer,
so you can simultaneously acquire two waveforms and analyze them with the highest
resolution and detail. If an anomaly flashes by on the screen, just press the Replay
button to see it again.
Connect-and-View Automatic triggering for an instant, stable display
Scope users know how difficult triggering can be. Wrong settings show unstable and sometimes wrong results. Fluke's unique Connect-and-View recognizes signal patterns, and automatically sets up correct triggering. It provides a stable, reliable and repeatable display of virtually any signal, including motor drive and control signals, without touching a button. Signal changes are instantly recognized and settings adjusted for, once again, a stable display. Benefit from the speed and convenience when measuring a number of test points in quick secession, unlike ordinary AutoSet/AutoRanging scopes.
Automatic capture and replay of 100 screens
Scope users know how frustrating it is to see a one-time anomaly flash by never to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can "freeze" the last 100 screens and scroll through picture-by-picture or replay as a "live" animation. Cursors can be used for further analysis. You can even use the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100 captured screens with individual time stamps can be stored for later recall or download to a PC.
Deep memory for high-resolution ScopeRecord
The memory stores 27,500 points per input for high resolution recording of events up to 30 hours, and still captures fast intermittents and glitches as short as 50 nsec. This continuous roll mode also stores events like motion profiles, UPS, power supply and motor start-ups. And the 100X zoom your can look at the smallest of details, like individual power cycles. Two of these 27,500 point recordings can be stored for later analysis.
Advanced trigger modes
A wide choice of automatic and manual trigger modes gives you the flexibility to capture just about any signal you'll encounter. Connect-and-View triggering is ideal for fast and easy checking of multiple testpoints. The manual modes include time delay, video and pulse-width triggering. A fully isolated external trigger input is included for troubleshooting time relationships between two input signals synchronized to a third signal.
Analysis PowerUse TrendPlot to help find intermittents, fastFor analysis of waveforms, ScopeRecord and TrendPlot recordings, the ScopeMeter features 24 automatic measurements, cursors, zoom and a real-time clock. The analysis can be made directly or later when back at the office. Up to 2 recordings and 10 scope screens can be stored for analysis, printout or download to a PC.
Measure from mV to kVThe toughest faults to find are those once-in-a-while intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connections. Other factors, like line outages and sags, or the starting and stopping of a motor can also cause a machine to stop. You may not be around to see it - Fluke's ScopeMeter will. In this "paperless recorder" mode, you can plot the minimum and maximum peak values and average over time - up to 16 days. The two inputs can plot any combination of volts, amps, temperature, frequency and phase, with time and date stamp, to help lead you to the cause of those faults quickly.
The ScopeMeter 190 Series with three independently floating isolated inputs is safety certified for measurements in 1000V CAT II and 600V CAT III environments. And the standard probes cover a wide application range from mV to kV, making the ScopeMeter 190 ideal for micro electronics to electrical power applications.
A versatile test-toolJust like the industrial ScopeMeter 123, the ScopeMeter 190 is a three-in-one instrument incorporating a scope, multimeter and paperless recorder. The rechargeable NiMH battery provides four hours of continuous operation, and takes just four hours to recharge. Battery saving and auto power down functions take you easily through the working day.
| Oscilloscope Mode | |
| Vertical Deflection | Bandwidth:
Rise time:
Bandwidth limiter: User selectable 10 kHz or 20 MHz Number of inputs: 2 plus external trigger. All isolated from
each other and ground. Input coupling: AC, DC with ground level indicator Input sensitivity: 5 mV/div to100 V/div Input voltage: See general specifications for maximum rating Vertical resolution: 8 bit Accuracy: ±(1.5% of reading + 0.04 x range/div) |
| Horizontal | Maximum real-time sample rate:
Number of digitizers: 2 Time base range:
Maximum record length: 1,000 points per input Accuracy: ± (0.01% of reading + 1 pixel) Glitch capture: 50 nsec (5
µsec/div to 1 min/div) Faster time bases have higher sample rates than |
| Display and acquisition | Display modes: Input A, input B, dual, average, persistence, invert,
replay Acquisition modes: Normal, auto, single shot, ScopeRecord, roll, glitch capture |
| Trigger and delay | Source: Input A, input B, external trigger input. All input references
isolated from each other and ground. Modes: Automatic Connect-and-View, free run,
single shot, edge, delay, video, video line, selectable pulse width Connect-and-View: Advanced automatic triggering that
recognizes signal patterns, automatically sets up and continuously adjusts triggering,
time base and amplitude. Automatically displays stable waveforms of complex and dynamic
signals like motor drive and control signals. Video triggering: NTSC, PAL, PAL+, SECAM. Includes field 1
and 2 and line select. Pulse width triggering: Pulse width qualified by time. Allows
for triggering |
| Automatic capture of 100 screens | The instrument ALWAYS memorizes last 100 screens (no user interaction or
setup required). When an anomaly occurs on screen, theres 10 seconds to press HOLD
and review it. If one sets up the instrument for triggering on glitches or intermittent
anomalies the unit operates in baby-sit mode and will capture 100 events. Replay: Manual or continuous replay. Displays the
captured 100 screens as a live animation. The contents can also be viewed by
manually scrolling backwards and forwards screen by screen. |
| Automatic scope measurements | VDC, VAC rms, VAC+DC, Vpeak max, Vpeak min, Vpeak to peak,
frequency (Hz), positive pulse width, negative pulse width, positive duty cycle, negative
duty cycle, amp AC, amp DC, amp AC+DC, power factor, watts, VA, VA reactive, phase,
temperature °C, temperature °F, dBV, dBm into 50W and 600W |
| Cursor Measurements | Source: Input A or B Dual horizontal lines: Voltage at cursor 1 and 2,
voltage between cursors Dual vertical lines: Time between cursors, voltage between
markers Single vertical line: Min-Max and Average voltage at cursor
position |
| Zoom | Up to 8x horizontal zoom |
| Meter Mode | |
| General | Via 4 mm banana inputs. Fully isolated from scope inputs and
scope ground. The specified accuracy is valid over the temperature range 18 °C to 28 °C
(15 °F to 33 °F). Add 10 % of specified accuracy for each degree °C below 18 °C or
above 28 °C (15 °F to 33 °F). |
| Maximum resolution | 5,000 counts |
| Voltmeter ranges | 500mV, 5V, 50V, 500V, 1,000V |
| Accuracy | VDC: ± (0.5 % + 5 counts) VAC true rms DC to 60 Hz: ± (1 % + 10 counts) 60 Hz to 1 kHz: ± (2.5 % + 15 counts) |
| Ohms | Ranges: 500W, 5kW, 50kW, 500kW, 5MW, 30MW Accuracy: ± (0.6 % + 5 counts) |
| Other meter functions | Continuity: Beeper on < 30W (± 10W) Diode test: Up to 2.8V Amps: Amp DC, Amp AC, Amp AC+DC using an Temperature (°C, °F): With optional accessories. Input impedance: 1 MW ± 1% // 10 pF ± 2 pF |
| Recorder Mode | |
| ScopeRecord-roll mode | Dual input waveform storage mode. Source and display: Input A, Input B, Dual Memory depth: 27,500 points per input. Each point consist of
Min-Max pair. Min-Max values: Min-Max values are measured at high sample rate ensuring capture and display of glitches Sample Recording Settings:
Set Time base range = 2 min/div:
Recording modes: Single sweep, continuous roll, start on
external trigger Horizontal scale: Time from start, time of day Zoom: Up to 100 x zoom |
| TrendPlot Recording | Dual input electronic paperless chart recorder. Plots, displays and stores
meter and scope measurements. Source and display: Input A, Input B and DMM input Memory depth: 13,500 points record per input. Per record
point a minimum, maximum and average value, and a time and date stamp are stored. Ranges: 10 s/div to 20 min/div in normal view mode. 10
min/div to 24 hour/div in view-all mode (overview of total record) Recorded timespan: Up to 8 days with a resolution of 1 minute Recording mode: Continuous roll Measurement speed: 2.5 measurements per second maximum Horizontal scale: Time from start, time of day Zoom: Up to 64x zoom |
| Cursor measurements - All Recorder Modes | Source: Input A, B or DMM input Dual vertical lines: Min-Max or Average voltage. Time
between cursors. |
| General Specifications | |
| Case | Design: Rugged, shock proof with integrated protective holster Drip and dust proof: IP51 according to IEC529 according to MIL-T28800E, Type III, Class 3, Style B |
| Display | Bright LCD with CCFL backlight, 35/60 cd/m2 without/with power adapter. Size: 105 x 79 mm (4.1 x 3.1 inches) Resolution: 240 x 240 pixels temperature compensated |
| Memory Save and Recall | Scope memories: 10 memory locations that each can contain two
waveforms plus corresponding setup. Recorder memories: 2 memory locations that each can contain 100 captured dual input scope screens, or a dual input ScopeRecord (27,500 Min-Max pairs per input), or a dual input Trendplot (13,500 Min-Max pairs per input). |
| Real-time Clock | Time and date stamp for ScopeRecord, 100 captured screens and Trendplots. |
| Power | Line power: Country specific line voltage adapter/battery charger
included Battery power: Rechargeable NiMH (installed) Battery operating time: 4 hours Battery charging time: 4 hours |
| Mechanical data | Size: 256 x 169 x 64 mm (10.1 x 6.6 x 2.5 inches) Weight: 1.95 kg (4.3 lbs) |
| Safety | Compliance: EN61010-1 (1993) Pollution degree 2, UL 3111-1 (1994), CAN/CSA C22.2 No.1010.1 (1992), ANSI/ISA S82.01 (1994) |
| Input voltage ratings | Maximum probe voltage: 1,000V CAT II, 600V CAT III (Maximum voltage between 10:1 probe tip (VP190) and reference lead) Floating voltage: 1,000V CAT II, 600V CAT III Independently isolated: 1,000V CAT II, 600V CAT III Maximum voltage on BNC input directly |
| Environmental | Operating temperature: 0 °C to +50 °C Storage temperature: -20 °C to +60 °C Humidity Maximum operating altitude: 3,000 m (10,000 feet) Maximum storage altitude: 12 km (40,000 feet) |
| Optically isolated PC/Printer interface | To printer: Supports HP Laserjet®,Deskjet®,Epson
FX/LQ® and postscript printers via optional PAC 91 To PC: Transfer instrument settings, screen images and waveform data, compatible with FlukeView®software for Windows® via optional PM9080. |
| Warranty | 3 years |
| Model Name | Accessory or Option Description |
| 80i-1000s | 1000A AC Current Probe |
| 80i-110s | 100A AC/DC Current Probe |
| 80T-150U | Universal Temperature Probe |
| 80T-IR | Non-Contact Infrared Temperature Probe |
| 80TK | Thermocouple Module |
| AC120 | Alligator Clips (Set of 3: Red, Gray, Black) |
| AC20 | Industrial Test Clips |
| AC80 | Hook-Style Test Clips |
| AC83 | Pin-Grabber Test Clips |
| AC85A | Large Jaw Alligator Clips |
| AS200-G | Probe Accessory Set, Gray |
| AS200-R | Probe Accessory Set, Red |
| BC190 | Line voltage adapter / battery charger |
| BP190 | Rechargeable battery pack (installed) |
| C190 | Hard carrying case |
| CS20MA | Current shunt 4-20mA |
| DP120 | Differential Probe |
| HC120 | Hook Clips (Set of 2: Red, Gray) |
| i2000flex | Flexible 2000A AC Current Probe |
| i200S | AC Current Clamp |
| i3000s | 3000A AC Current Probe |
| MA190 | Accessory kit for use with Fluke 190 Series ScopeMeters, optimized for use on medical imaging and video equipment. |
| MS190 | Software extension kit. See also MS 190 Compatibility. |
| PM 9080/001 | Optically Isolated RS-232 Adapter/Cable |
| SCC190 | Carrying case, FlukeView Software and optically isolated serial interface cable PM9080 for Fluke 190 Series (connects to standard RS-232 port of a PC). |
| SW90W | FlukeViewâ Software for Fluke 190, 123 or 90 B Series |
| TL20 | 63" Test Lead Set |
| TL75 | 48" Hardpoint Test Lead Set |
| TP1 | Slim Reach Test Probe |
| TP2 | Slim Reach Test Probe |
| TP20 | Industrial Test Probe |
| TP4 | Slim Reach Test Probe |
| TP80 | Electronic Test Probe |
| VPS121 | 1:1 Voltage Probe Set 12 MHz 1.2m |
| VPS200-G | 10:1 Voltage Probe Set, Gray 200 MHz |
| VPS200-R | 10:1 Voltage Probe Set, Red 200 MHz |
| VPS201 | 100:1 Voltage Probe Set 200 MHz |
| VPS250 | 10:1 Voltage Probe Set 75 MHz 2.5m |
TO ORDER ACCESSORIES CLICK HERE